Recalls and advisories
Every notice we have issued, including the small ones. Affected customers are contacted directly; this page is the public record.
- Open notices
- 2
- Customer contact
- Direct, before publication here
- Security reports
- security@nexaformlabs.com
- Adverse events
- +1 (612) 555-0199, 24 hours
Notices
Newest first. Status is updated as corrective actions complete.
| Reference | Date | Type | Products | Summary | Status |
|---|---|---|---|---|---|
| NXA-2026-007 | Sep 29, 2026 | Security advisory | Formcloud on premises 4.3.1 and earlier | A bundled TLS library had a published vulnerability. Not exploitable in the default configuration. Fixed in 4.3.2. | Open |
| NXA-2026-006 | Sep 15, 2026 | Software advisory | Axon Sense 2, firmware 2.13.x | A skin contact flag could be raised for a single sample during an adhesive change. No measurement data affected. Fixed in 2.14.1. | Open |
| NXA-2026-004 | May 12, 2026 | Labeling update | Corta monitor | Instructions for use updated with additional MR conditional scan parameters. No change to the device. | Closed |
| NXA-2026-002 | Mar 3, 2026 | Field safety notice | Fieldmesh E-series probe, lot 25-118 | Some probes in one lot read up to 0.6 °C high above 6 °C. Replacement probes shipped to all affected sites. | Corrective action complete |
| NXA-2025-011 | Nov 18, 2025 | Software advisory | Formcloud 4.1 | Canary halt thresholds were not applied to groups created by API. Fixed in 4.1.3 with no customer action needed. | Closed |
| NXA-2025-008 | Aug 4, 2025 | Field safety notice | Axon Sense 2 charging cradle, NX-ACC-1150, early units | A cradle could stop charging without showing a fault light. Cradles exchanged; no patient impact reported. | Corrective action complete |
| NXA-2025-005 | May 21, 2025 | Security advisory | Nexa Edge Home, firmware 4.x | A debug interface was reachable over Bluetooth during the first boot only. Fixed in 5.0.1, applied automatically. | Closed |
| NXA-2025-002 | Feb 10, 2025 | Labeling update | Lattice Bench LB-32 | Specification sheet corrected: maximum cascade is four units, not eight. | Closed |
What each type means
Field safety notice
Action is needed on devices in the field: a replacement, an inspection, or a change in use. Affected customers are contacted directly and asked to confirm receipt.
Software advisory
A software or firmware defect with a fix available. We say whether any action is needed and whether data was affected.
Security advisory
A confirmed vulnerability, its severity, the affected versions and the fix. Published after a fix is available to customers.
Labeling update
A change to instructions for use, specifications or other labeling, without a change to the device.
Received a notice?
The notice tells you what to do and by when. If anything in it is unclear, call quality, not your sales contact.